Heating boiler Ariston gas double-circuit. Double-circuit gas wall-mounted boilers Ariston

Italian manufacturers have been producing Ariston brand boilers for quite a long time. Boilers became popular with us during the period of intensive individual construction of buildings, in houses where work central system heating leaves much to be desired.

Ariston excelled in his technical abilities, fell in love with the people due to the variety of configurations, a wide range of systems, and is still in demand among consumers.

The lineup

The line of models of double-circuit boilers, unlike single-circuit boilers, is more in demand, since the models are designed for heating rooms and supplying hot water.

BCS 24 FF (with closed combustion chamber) and Uno 24 FF (with open combustion chamber)


Most buyers choose Ariston of these brands. In addition to the operating instructions, all elements of the heating system are attached to the device, which you can manage every day and without special skills.

Efficiency reaches 95%, power - 24 - 26 kW, hot water capacity - up to 14 liters per minute.

Genus


It is considered the most functional model. There is a display on the case, all the parameters of the device are reflected both inside and outside. Ariston of this brand is compact, equipped with a modulated burner that helps to save fuel, and there is also a programmer with a built-in timer.

You can set the program for the device immediately for the whole day, lower or increase the temperature, set the parameters for the unit at your discretion. The volume of the tank is 8 liters, the air vent is automatic, a self-diagnosis system is built in, all information is displayed on the display.

Egis Plus

Adapted for operation in the Russian climate. Models are not afraid of voltage drops in gas pressure in pipes. The unit has 2 heat exchangers: copper and stainless, as well as a condensate collector for uninterrupted operation at outdoor temperatures below -52 degrees. On the panel - LED indexing.

All information can be read on the display.

Advantages and disadvantages

Like any system, the Aristons are not perfect.

Its undoubted advantages are:

  1. Security. The system is safe, even though the fuel is explosive.
  2. Efficiency is high, when burned, the gas leaves practically no residues, the heating is completely spent on the needs of the owners, heat is retained in the room.

The disadvantages include:

  1. Don't choose a cat l for space heating
  2. For boiler installation requires a separate, and not small room, because next to it you still need to place fire fighting system, in case of fire
  3. The pressure in gas boilers is not stable, sharp jumps are possible, which is also explosive. Required additional installation adjustment unit, burners, the device can quickly fail.

Specifications and selection criteria


When choosing, it is important to pay attention to the following characteristics:

  1. Boiler power, consisting in the calculation of heat. Without certain knowledge, it is extremely difficult to do it yourself. The calculation takes into account the area of ​​​​openings of all windows in the dwelling, the percentage of heat transfer from radiators, and the heat permeability of the walls. Only taking into account these parameters, the choice will be optimal, and you will not have to overpay for excess electricity. The average energy consumption coefficient is 100 W per 1 meter of housing. When combining a heated room with an unheated one, the indicator will increase by half, up to 160 V.
  2. The presence of a flue for gas outlet.
  3. The presence of a circular pump in Ariston. Without it, you can not leave the device unattended in winter, the pipes may burst. The control system should be simple and understandable to the average user. A device stuffed with various functions is unlikely to be needed for heating water, and the cost of such multifunctional blocks increases significantly. Today they are not in demand.
  4. Heat exchanger material. It is better if it is steel, cast iron, or copper. It is advantageous to have a copper unit, it has a high efficiency, all the resulting temperature is given to the carriers. However, the strength of copper is not different. Performance and durability are higher for cast iron boilers, the alloy is reliable and durable.
  5. The performance of the boiler depends on the water consumption for the needs of the family. The boiler is not suitable for heating large areas, but with the heating of water, he can handle it quite well. It is not difficult to calculate the water consumption, knowing that 5-6 liters of water flows out of the boiler per minute. Up to 12 liters pour out of the shower during the same time. It is necessary to count the number of points connected to the boiler and make a total calculation.

Manufacturers in the documentation for the boiler indicate the difference temperature regime before heating, compared with the temperature after heating. When choosing a model, in addition to the water flow rate, take into account the water temperature before starting to heat the boiler.

If up to 5 liters of water per minute flows out of the tap, the water temperature before heating should be at least 7-8 degrees. If there are 3 points in the apartment, you need 5 + 5 + 5 \u003d 15 liters. When the boiler is heated to 40 degrees, minus 7 degrees, 33 degrees will come out before heating, which is quite acceptable for washing kitchen utensils and for taking a shower.

Advantage modern units given to floor boilers. The operation of Ariston data is not affected by the quality of the power supply, models with cast iron heat exchanger more reliable and durable.

Price and reviews


You can buy a new Ariston for 20-25 thousand rubles. Foreign analogues, novelties with many functions and built-in LCD displays are more expensive, but they are also of better quality. Although our domestic producers nothing worse. It is better to overpay, but buy a reliable, trouble-free thing, taking into account all the described parameters.

Gas boilers Ariston appeared on the Russian heating market among the first. Thanks in large part to its worldwide famous brand, this Italian manufacturer gas heating equipment quite quickly managed to "win" the domestic buyer and achieve high sales dynamics.

Ariston gas boiler, reviews of the owners of which help to better decide on a purchase, we can often find on different sites and in online stores. Modern feature set and good design, good technical characteristics and big choice models are clear advantage when buying a device, even despite the somewhat inflated prices.

But today we will consider not only the pros, but also the disadvantages of Ariston mounted boilers, having studied their device and features of the models, using the instruction manual, photos, reviews of customers and specialists.

Model range of wall-mounted double-circuit gas boilers Ariston

The Italian manufacturer is represented on Russian market enough a wide range wall gas boilers. We can meet gas boilers Ariston double-circuit and single-circuit, traditional and condensing, with storage boiler and without it.

In addition, like most competitors, Ariston gas heating boilers are available with a closed combustion chamber (turbocharged) and open (atmospheric). For devices with forced draft, a chimney outlet is provided horizontally through the wall, additionally buying a special one for it with a pipe diameter of 60/100 mm.

Gas boilers Ariston: product range

To date, the Italian company produces several modifications of its traditional double-circuit gas boilers:

- Ariston BS 15 FF, 24 FF and 24 II;

- Ariston Cares X 15 CF and 15 FF, 18 FF, 24 CF and 24FF;

- Ariston HS 15 CF and 15 FF, 18 FF, 24 CF and 24FF;

- Ariston Clas X 24 FF, 28 FF and 24 CF;

- Ariston Egis Plus and Premium;

— Ariston Genus X;

— Ariston Alteas X.

Single-circuit gas boiler Ariston with the ability to connect a boiler indirect heating represented by only one model "Ariston Cares X System" with power from 15 to 32 kW with closed and open combustion chambers.

Double-circuit gas boilers Ariston are available with a capacity of 15, 18, 24 and 28 kW. The most popular modification is a 24 kW device that can heat a house up to 200-230 m2. Turbocharged boilers have the symbols FF in their name, atmospheric - CF.

Peculiarities gas boiler Ariston Cares X: instruction, device

Ariston Cares X 24FF

This model is one of the budget in price segment up to 35,000 rubles, and due to this the most popular, judging by the number of reviews from the owners of the Ariston boiler. But even for a small amount, the buyer receives a modern wall-mounted gas boiler with a nice appearance, button control and LCD display, as well as the entire set of necessary functions.

As on all models of Ariston wall-mounted gas boilers, the Cares X series devices are equipped with: circulation pump stamps Wilo with automatic air vent and gas valve SIT. In addition, they are equipped with a boiler safety group and a membrane expansion tank for 8 liters.

Gas boiler "Ariston Cares X" has two heat exchangers: the main copper with aluminum coated for the heating circuit and a compact stainless steel secondary for the DHW circuit. The capacity of this secondary heat exchanger for the 24 kW Ariston Cares X 24 FF (CF) models is 13.6 l/min. Consider the device of a double-circuit gas boiler Ariston Cares X 24 FF NG:

Double-circuit gas boiler Ariston

1 - outlet for a coaxial chimney;
2 - pneumatic relay;
3 - collector for condensate;
4 - main heat exchanger for heating;
6 and 19 - temperature sensors at the inlet and outlet of the heating circuit;
7 - Polidoro gas burner;
8 - ignition electrodes;
9 - secondary heat exchanger for hot water supply;
10 - gas valve SIT;
11 - safety valve for 3 bars;
12 - ignition block;
13 - pressure gauge;
14 - tap for feeding the heating system;
15 - filter;
16 - DHW flow sensor;
17 - Wilo circulation pump;
18 - pressure switch;
20 - three-way valve drive;
21 - burner flame control sensor;
22 - combustion chamber;
23 - expansion tank;
24 - fan (turbine).

The "winter-summer" mode and room thermostat help to reduce gas costs. In summer, the boiler can only work on the DHW circuit, while in winter the device works economically thanks to the modulating gas burner. Room thermostat not included in the boiler package, but it can always be bought separately.

Boilers of this series have in their device temperature sensors installed on the "supply" and "return", temperature running water, flame and draft control sensors. In addition, the devices are equipped with a security system: protection against low pressure water, the function of protection against freezing of the system and its overheating.

The Ariston gas boiler is adapted to Russian conditions, such as voltage drops in the power grid, weak pressure gas and low temperature air outside the window. But, even despite this, the manufacturer himself recommends connecting the boiler through.

This recommendation applies not only to boilers of this brand, but also to other wall-mounted gas boilers of any manufacturer. If it suddenly fails electronic board boiler due to a power surge, then this case will not be covered by the warranty.

Technical characteristics of the double-circuit gas boiler Ariston Cares X

Ariston gas boiler: technical specifications

Advantages of Ariston gas boilers:

- a very large selection of models;
- a prestigious global brand;
- Italian assembly;
- two heat exchangers;
— adaptation to Russian conditions.

Disadvantages of gas boilers Ariston:

- overcharge;
— accessories Chinese made;
- the main direction of the company is the production of storage water heaters.

Dual circuit gas boilers Ariston

Instructions for Gas wall boilers Ariston

On this page you can find and download instructions for Ariston gas wall-mounted boilers in pdf format.

      Gas wall-mounted boilers Ariston series GENUS 24 FF, GENUS 28 FF, GENUS 36 FF, GENUS 24 CF, GENUS 28 CF. User manual. Language: RU, RO | pdf 786.93 Kb

      Gas wall-mounted boilers Ariston of the GENUS 24 CF, GENUS 28 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1.09 Mb

      Gas wall-mounted boilers Ariston GENUS 24 FF, GENUS 28 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1.07 Mb

      Gas wall-mounted boilers Ariston GENUS 24 FF, GENUS 28 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 5.05 Mb

      Gas wall-mounted boilers Ariston of the GENUS 24 CF, GENUS 28 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 3.14 Mb

      Gas wall-mounted boilers Ariston of the GENUS 36 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 893.17 Kb

      Gas wall-mounted boilers Ariston GENUS 36 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.00 Mb

      Gas wall-mounted boilers Ariston series GENUS 24 CF, GENUS 28 CF, GENUS 24 FF, GENUS 28 FF, GENUS 35 FF. User manual. Language: RU, RO | pdf 7.32 Mb

      Wall mounted single-circuit boilers CLAS System 24 FF, CLAS System 28 FF, CLAS System 32 FF. Installation and maintenance instructions. 2008 | pdf 4.71 Mb

      Gas wall-mounted single-circuit boilers CLAS System 15 FF, CLAS System 24 FF, CLAS System 28 FF, CLAS System 32 FF, CLAS System 15 CF, CLAS System 24 CF, CLAS System 28 CF. User manual. 2008 | pdf 1.24 Mb

      Gas wall double-circuit boilers EGIS 24 CF. Installation and maintenance instructions. 2008 | pdf 1.01 Mb

      Gas wall-mounted double-circuit boilers EGIS 24 FF. Installation and maintenance instructions. 2008 | pdf 1.24 Mb

      Gas wall-mounted double-circuit boilers EGIS 24 FF, EGIS 24 CF. User manual. 2008 | pdf 497.92 Kb

      Gas wall-mounted boilers Ariston series BS 24 FF, BS 24 CF. User manual. Language: RU, PL | pdf 439.96 Kb

      Gas wall-mounted boilers Ariston BS 24 CF series. Installation and maintenance instructions. Language: RU, PL | pdf 1.86 Mb

      Gas wall-mounted boilers Ariston BS 24 CF series for heating and hot water supply. Passport. Language: RU, PL | pdf 1.05 Mb

      Gas wall-mounted boilers Ariston BS 24 FF series for heating and hot water supply. Passport. Language: RU, PL | pdf 1.08 Mb

      Gas wall-mounted boilers Ariston BS 24 FF series. Installation and maintenance instructions. Language: RU, PL | pdf 2.33 Mb

      Gas wall-mounted boilers Ariston BS II 15 FF series. User manual. Language: RU, UA, RO | pdf 228.38 Kb

      Gas wall-mounted boilers Ariston BS II 15 FF series. Installation and maintenance instructions. Language: RU, UA, RO | pdf 1.71 Mb

      Gas wall-mounted boilers Ariston BS II 15 FF series for heating and hot water supply. Passport. Language: RU, UA, RO | pdf 1012.93 Kb

      Gas wall-mounted boilers Ariston BS II 24 FF series. Installation and maintenance instructions. Language: RU, UA, RO | pdf 1.88 Mb

      Gas wall-mounted boilers Ariston BS II 24 FF series for heating and hot water supply. Passport. Language: RU, UA, RO | pdf 1018.39 Kb

      Gas wall-mounted boilers Ariston BS II 24 CF series for heating and hot water supply. Passport. Language: RU, UA, RO | pdf 1005.51 Kb

      Gas wall-mounted boilers Ariston BS II 24 CF series. Installation and maintenance instructions. Language: RU, UA, RO | pdf 1.38 Mb

      Gas wall-mounted boilers Ariston series BS II 24 FF, BS II 24 CF. User manual. Language: RU, UA, RO | pdf 246.76 Kb

      Gas wall-mounted boilers Ariston series CLAS 24 FF, CLAS 28 FF, CLAS 24 CF. User manual. Language: RU, RO | pdf 661.98 Kb

      Gas wall-mounted boilers Ariston CLAS 24 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.28 Mb

      Gas wall-mounted boilers Ariston of the CLAS 24 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1005.77 Kb

      Gas wall-mounted boilers Ariston of the CLAS 24 FF, CLAS 28 FF series for heating and hot water supply. Installation and maintenance instructions. Language: RU, RO | pdf 2.78 Mb

      Gas wall-mounted boilers Ariston of the CLAS 24 FF, CLAS 28 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1.13 Mb

      Gas wall-mounted boilers Ariston series CLAS B, CLAS B Premium: CLAS B 24 CF, CLAS B 24 FF, CLAS B 30 FF, CLAS B Premium 24, CLAS B Premium 35. Instruction manual. Language: RU, PL, CZ, RO, HU | pdf 2.52 Mb

      Gas wall-mounted boilers Ariston CLAS B 24 CF series. Installation and maintenance instructions. Language: RU, PL, CZ, RO, HU | pdf 7.20 Mb

      Gas wall-mounted boilers Ariston of the CLAS B 24 CF series for heating and hot water supply. Passport. Language: RU, PL, CZ, RO, HU | pdf 1.09 Mb

      Gas wall-mounted boilers Ariston of the CLAS B 24 FF, CLAS B 30 FF series for heating and hot water supply. Installation and maintenance instructions. Language: RU, PL, CZ, RO, HU | pdf 8.84 Mb

      Gas wall-mounted boilers Ariston of the CLAS B 24 FF, CLAS B 30 FF series for heating and hot water supply. Passport. Language: RU, PL, CZ, RO, HU | pdf 1.15 Mb

      Ariston gas wall-mounted boilers of the CLAS EVO 24 FF, CLAS EVO 28 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 28 FF, CLAS EVO SYSTEM 32 FF, CLAS EVO 24 CF, CLAS EVO SYSTEM 24 CF, CLAS EVO SYSTEM 28 CF series. User manual. Language: RU, RO | pdf 373.49 Kb

      Gas wall-mounted boilers Ariston series CLAS EVO 24 CF, CLAS EVO SYSTEM 24 CF, CLAS EVO SYSTEM 28 CF. Installation and maintenance instructions. Language: RU, RO | pdf 1.87 Mb

      Gas wall-mounted boilers Ariston of the CLAS EVO 24 CF, CLAS EVO SYSTEM 24 CF, CLAS EVO SYSTEM 28 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 987.40 Kb

      Ariston gas wall-mounted boilers of the CLAS EVO 24 FF, CLAS EVO 28 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 28 FF, CLAS EVO SYSTEM 32 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.60 Mb

      Ariston gas wall-mounted boilers of the CLAS EVO 24 FF, CLAS EVO 28 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 28 FF, CLAS EVO SYSTEM 32 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 990.97 Kb

      Ariston gas wall-mounted boilers of the CLAS EVO SYSTEM 15 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 32 FF, CLAS EVO SYSTEM 15 CF, CLAS EVO SYSTEM 24 CF series. User manual. Language: RU | pdf 306.18 Kb

      Gas wall-mounted boilers Ariston series CLAS EVO SYSTEM 15 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 32 FF. Installation and maintenance instructions. Language: RU | pdf 2.33 Mb

      Gas wall-mounted boilers Ariston of the CLAS EVO SYSTEM 15 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 32 FF series for heating and hot water supply. Passport. Language: RU | pdf 946.87 Kb

      Gas wall-mounted boilers Ariston series EGIS PLUS 24 FF, EGIS PLUS 24 CF. User manual. Language: RU, RO | pdf 204.57 Kb

      Gas wall-mounted boilers Ariston of the EGIS PLUS 24 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.29 Mb

      Gas wall-mounted boilers Ariston of the EGIS PLUS 24 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 973.91 Kb

      Gas wall-mounted boilers Ariston of the EGIS PLUS 24 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 934.35 Kb

      Gas wall-mounted boilers Ariston of the EGIS PLUS 24 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 1.69 Mb

      Gas wall-mounted boilers Ariston series GENUS EVO 24 FF, GENUS EVO 30 FF, GENUS EVO 32 FF, GENUS EVO 35 FF, GENUS EVO 24 CF, GENUS EVO 30 CF. User manual. Language: RU, RO | pdf 446.18 Kb

      Gas wall-mounted boilers Ariston of the GENUS EVO 24 FF, GENUS EVO 30 FF, GENUS EVO 32 FF, GENUS EVO 35 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 991.20 Kb

      Gas wall-mounted boilers Ariston of the GENUS EVO 24 CF, GENUS EVO 30 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1019.57 Kb

      Gas wall-mounted boilers Ariston series GENUS EVO 24 FF, GENUS EVO 30 FF, GENUS EVO 32 FF, GENUS EVO 35 FF. Installation and maintenance instructions. Language: RU, RO | pdf 2.72 Mb

      Gas wall-mounted boilers Ariston GENUS EVO 24 CF, GENUS EVO 30 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.19 Mb

When conducting overhaul may need to install new system heating. Today, a huge range of heating boilers is offered, the differences between which are the fuel used, the manufacturer’s power, etc. Note that the Ariston double-circuit gas boiler is in greatest demand, which has excellent technical specifications and accessibility.

Gas equipment manufactured by Ariston

Gas equipment manufactured by Ariston, depending on the model in question, is designed for installation in autonomous systems heating area up to 500 m 2. Note that these models are capable of not only working to heat the coolant, but are also able to provide the user with hot water.

The double-circuit wall-mounted gas boiler Ariston is distinguished by its compact external dimensions, as well as simplicity and ease of operation and maintenance. For the installation of equipment, it is not necessary to allocate a separate room, as, for example, for liquid and solid fuel heaters.

Due to the wide power range, Ariston equipment can be easily selected for installation in a specific system, based on the characteristics of the room to be heated.

List of mandatory functions in heating equipment

  1. The language menu on absolutely all models offers the Russian language.
  2. The AUTO function is set, which allows you to automatically adjust the power based on the internal and outdoor temperature air.
  3. Absolutely all Ariston units have heat and sound insulation.
  4. The manufacturer gives a two-year guarantee for all its products of the traditional type, and three years for the condensing type.

Safety in the operation of the equipment is ensured by the following built-in functions:

  • semi-automatic make-up;
  • pumping air out of the system;
  • blocking the operation of the circulation pump;
  • protection against freezing and scale formation.

Gas heating boilers double-circuit turbocharged Ariston are simple and easy to operate and maintain.

The main advantages of Ariston equipment

Ariston equipment is offered in two versions: wall-mounted and floor type. The former are used for installation in the heating systems of private houses, in which, in addition to heating, it is important to receive hot water. Depending on the model, the equipment may be:

  • with open cam combustion (combustion products are discharged naturally);
  • with a closed combustion chamber (removal is carried out by force).

Closed chamber equipment is connected to coaxial chimney. The difference lies in the fact that these models have a built-in fan, thanks to which the combustion products are removed in a timely manner.

The main advantage of devices of the second type is high safety, as well as the fact that air is taken from outside the room, devices of the first type, the oxygen necessary for normal combustion gas is taken from the premises.

It is important to note that Ariston gas double-circuit wall-mounted boilers stop working for heating the coolant immediately after the hot water intake is turned on. This point is important to consider when choosing and buying a device.

Outdoor appliances have a large power range. This equipment is excellent for use in systems autonomous heating living quarters of any size. Usually, floor units are not designed for heating water, so if this issue is relevant for you, you will have to buy a separate boiler.

Design features and equipment arrangement

All offered options for gas boilers differ in the type of combustion chamber: closed or open. If the device is equipped with an open chamber, then it will need to be connected to a chimney, while the air is taken from the room in which the unit is installed.

In the event that the Ariston wall-mounted double-circuit gas heating boiler is equipped with a closed chamber, then the removal of combustion products occurs forcibly, using a built-in fan. Such equipment is connected to a coaxial chimney. Air intake is carried out from outside the room, which is a great advantage, since the operation of the device does not burn the oxygen in the room.

Gas wall-mounted double-circuit heating boilers Ariston have two heat exchangers in their design. One is for heating technical water, the second for heating the coolant. Their production can be carried out in several versions: bithermic, separate and with a built-in boiler.

The main characteristics of gas boilers "Ariston"

  • the menu of the device is displayed in Russian, if necessary, you can easily set the required temperature for heating the coolant and hot water;
  • high resistance to sudden voltage drops in the network;
  • the equipment will continue to work stably even at reduced pressure of water and gas in the respective systems;
  • ease and convenience in installation, maintenance and operation;
  • high operating efficiency.

As for the shortcomings of the equipment, it is important to note here the inability to simultaneously work on heating the coolant and sanitary water, but this problem, if desired, can be easily solved by installing a boiler.

The gas double-circuit wall-mounted boiler Ariston can have in its design special sensors for determining the internal and external air temperature. All operating parameters are displayed on the built-in display, which makes it easy to control work processes and, if necessary, make the necessary adjustments to them.

Causes of malfunctions of gas-type boilers

Even if the operating instructions for the Ariston gas boiler are thoroughly studied, it is impossible to insure that the device will not break. There are many reasons why equipment can fail, for example:

  • maintenance of the device was not performed in a timely manner or with violations;
  • insufficient air supply to the combustion chamber;
  • unprofessional repair or maintenance of control units or burner adjustment;
  • when carrying out maintenance, low-quality spare parts were used;
  • incorrect temperature setting.

There are other more complex breakdowns of gas heating boilers, which should only be repaired by a service employee. Therefore, regardless of the complexity and cause of the malfunction, the Ariston double-circuit gas boiler must be repaired and maintained by a master who has not only special tools and experience, but also a special permit for repair and maintenance of gas heating boilers.

Do not save on purchase, installation and connection gas equipment, trust the execution of all work processes only to professionals.

Gas boiler Ariston Genus EV - video

The most popular models of gas boilers "Ariston"

Genus Premium 35 NG is a condensing type device that is easy to program on various modes work. The advantage of the equipment is high efficiency. Double-circuit gas boilers Ariston, equipped with a closed combustion chamber, provide high safety and reliability of equipment in operation.

Exhaust gases are discharged through a coaxial chimney forcibly. It is important to note that the equipment is capable of self-diagnosis, which allows you to quickly identify a malfunction and take measures to eliminate it.

Equipment Egis 24 CF NG (EAA1) is equipped with an open combustion chamber. The unit is connected to a chimney, the diameter of which must be greater than 12.5 cm. Two heat exchangers are installed in the design of the device. Type of installation wall.

Ariston Clas is highly economical in operation. Today, options are offered, the power of which can range from 24 to 28 kW.

The combustion chamber in Ariston Clas can be closed or open. The design of the device is equipped with two heat exchangers. The main advantage lies in the ability to continue to work stably with a sharp drop in pressure in the gas line or water supply system.

If you decide to buy a wall-mounted double-circuit gas boiler Ariston of any other series, you can be sure that the equipment you purchase will also differ in quality, reliability and efficiency in operation.

Features of the choice of heating equipment

When choosing heating boilers, it is important to take into account the height of the ceilings, the area of ​​\u200b\u200bthe premises, the material from which the structure is built and interfloor ceilings, quality of window blocks . Lot useful information You can find out if you carefully study the instruction manual for the Ariston gas boiler. Having correctly determined all the above-mentioned parameters, you can find out what power the device will be most profitable to purchase.

Calculations should be performed according to the following scheme. If, for example, a house has an area of ​​​​150 m 2 with a ceiling height of 2.7 - 3 meters, windows, ceilings and walls are well insulated, then at the rate of 1 kW per 10 m 2, we get 15 kW of device power, to which it is recommended to add 10 %. As a result, we get the maximum required power of heating equipment. If, in addition to heating, there is a need for hot water, then 4 kW of power should be added to the result.

In addition to the considered parameter, there are others, which in no case should be forgotten when choosing. Therefore, if you doubt that you can properly deal with the choice of a gas boiler, then contact a specialist who, taking into account all the requirements and features of the house in which the device will be installed, will select it according to all the necessary parameters.

Despite the standardization of heating equipment, each manufacturer offers, albeit few, but different solutions. The Italian manufacturer of boilers - Ariston - also does just that. It's time to figure out how perfect its products are, and how it differs from the products promoted by competitors.



Peculiarities

A gas boiler is considered the most practical and economical source of heat in any area where pipes are laid. main gas pipelines. It is this equipment that largely determines how consumers will feel the advantages of heating with “blue” or liquefied fuel. Although Ariston boilers were created by Italian engineers, there are still specific Russian conditions properly taken into account.

The created systems were initially designed with the expectation of:

  • unstable and often low gas pressure;
  • insufficiently sustained tension;
  • contaminated water ingress;
  • extremely cold winters with heavy rainfall and violent winds.



The functional parameters of the systems are approximately the same, no type, no charge for specific model are of no particular importance. The main difference concerns external perception, the size of the boiler. Of course, one cannot but mention the fact that, like other manufacturers, there is a clear distinction between single-circuit and double-circuit models. A useful option is the auto function, when using which the adjustment to the necessary parameters occurs automatically. In addition, any boiler of the Italian concern is equipped with a built-in automated unit for resetting excess air, protected from freezing and accumulation of scale, other dirt.

Kinds

To properly evaluate the characteristics of wall-mounted boilers, you need to refer to individual models. And a special place among them is occupied by the double-circuit Alteas X. This device is classified as a premium heating technology, designed for the highest possible thermal performance. The designers took care of the possibility of remote control via the Wi-Fi module. In the presence of mobile internet You can monitor the operation of the device anywhere in the world.

Information is displayed through a matrix display. What exactly they will be depends on the consumer (everything is flexibly configured). The boiler menu is 100% Russified. The system uses a modulating pump that consumes 30% less electricity compared to simpler analogues. The device develops an efficiency of 93.6% at favorable conditions operation. In addition to purely technical and consumer advantages, the stylish appearance of the boiler is also important.


This model can be seriously competed with the Cares mechanism. It is also mounted on the wall and also works with two circuits at the same time. But at the same time, it ensures the effectiveness of work in 93.8%. Heating can be programmed, for this purpose compatible two-position control devices are usually used. Aluminum is used in the production of the primary heat exchanger premium with excellent corrosion resistance and thermal efficiency.

Secondary circuit in contact with tap water very durable and long lasting. At the same time, he is able to give in 60 seconds required heat 13.6 liters of water. Both in the heating circuit, and in the hot water supply system, and in the boiler feed channel, filters are installed to prevent the ingress of mechanical impurities. For all its excellence, Cares is indifferent to harsh operating conditions. Even if the pressure water will fall up to 5 mbar, and on the street the temperature drops to minus 52 degrees, this will not affect the quality of work.



In some cases, there is no need for hot water supply, you only need to heat the house (or vice versa). Such situations make the single-circuit boiler Ariston Clas X System quite relevant. The efficiency of high-quality gas combustion in this boiler reaches 93.6%. It is equipped with a two-speed pump and an LCD information display. In the appearance of the boiler, all the undoubted advantages of the Italian design school appear.

The best are used during production. construction materials , and special functions reduce the number of stops and starts of the boiler to a minimum. Can connect an external boiler to get stable hot water. As with the Cares model, the initial heat exchanger is made from high metallurgical grade aluminium. Depending on the specific subspecies, the gas combustion compartment can be either open or closed. Heat production for the heating circuit sometimes reaches 28, and for the plumbing - 31.8 kW.



Clas One is a double-circuit condensing boiler of the business category. According to the manufacturer, it is made with innovative additions. In particular, a specially developed heat exchanger of the latest generation, characterized by an increased diameter of pipes, was used. If street and apartment sensors are used, the system reaches efficiency group A+. The apparatus responsible for the suppression of working noises has been updated; storage tank for a mounted boiler with a power of 24 kW or other power must, for the most part, be purchased separately.


Connection

Knowing the wiring diagram for mounted Ariston boilers is very useful. Yes, the company prescribes that such work should be carried out exclusively by trained specialists. But they also need careful comprehensive control. The work is carried out in strict accordance with the instructions of SNiP. The prepared project is coordinated in the territorial bodies supervising gas safety.

The project must specify:

  • what are the actual parameters of the equipment;
  • where it will stand;
  • how the rest of the heating infrastructure will be implemented.



Important: even if these conditions are met, the installation itself must be carried out only by representatives of authorized service centers. It is possible to use hinged gas boilers only when they are placed in separate rooms (furnace or boiler rooms). The exact list of requirements depends on the power of the boiler and the type of working compartment. In the case of an open chamber, the approach is approximately the same as when using a conventional furnace, that is, a chimney is used to remove gases. The window facing the street must have an area of ​​​​at least 0.5 square meters. m, should also provide a sufficient area for maintenance.

Based practical experience, you can turn on the boiler without risk in the room:

  • up to 8 cu. m (with a maximum furnace power of 30 kW);
  • up to 13-14 cu. m (if they receive up to 60 kW of heat);
  • from 15 m3 and above (if 60-200 kW is generated).

The approach to closed combustion chambers is different. It uses a coaxial type of chimney, that is, a double pipe. Outdoor air moves into the furnace through the outer part, and gaseous combustion products leave through the inner part. Such devices are in any case equipped with fans connected to electrical network. Exactly closed type the combustion compartment is optimal in sanitary and environmental terms, therefore it is recommended for kitchens and bathrooms.

The choice of the height of the wall mount and the method of such attachment is critical. Proper fasteners are not always added to the supplied bracket. Therefore, sometimes they are chosen individually, focusing on the material of the wall and its parameters. It must be taken into account that the bracket must transfer the load from the installed device and at the same time keep it in a level position. For floor systems requirements are noticeably softer.



The entire surface of the wall adjacent to the heat generator, even if located at a considerable distance from it, must be covered with a fireproof layer. The lower point of the suspended device rises 0.8 m above the floor, the distance from the wall to the rear line of the boiler is at least 50 mm. Next, connect the main heating circuit. How many pipes need to be connected depends on the one-pipe or two-pipe version of the system. Before connecting, we must not forget about the dismantling of the plugs covering the boiler pipes.

It is advisable to mount a filter on the input. Even if the filtration is provided in the boiler itself, it is still better to avoid overloading it. Only a boiler connected to the water supply can be connected to the gas supply circuit. Note: This information is for informational purposes only. Only professionally trained and authorized specialists are allowed to connect gas boilers to gas pipelines!


Initially, a ball-type valve is placed at the input to the device. Before the device, a fuel consumption meter and a leak indicator are placed. Next comes the turn of the thermal alarm valve. If the temperature rises too high, it will block the flow of natural or liquefied gas farther. The next step is (for some boilers) connecting to the electrical network.

Most often, schemes are chosen that involve the use of three wires. Regardless of the scheme chosen, all wiring and devices connected to it must be grounded. It is very good when the boiler is connected to the mains through a voltage stabilizer. Having connected it to the electrical network, they are then engaged in the formation of an output to the chimney. Atmospheric boilers must have a separate channel for the discharge of combustion products.



At the time of installation, there should not be the slightest dirt and traces of soot or soot inside the chimney. vertical block after withdrawal from the device, the length to the nearest turn is equal to at least two diameters. Then begins the section where the pipe leans towards the boiler. It is recommended to reduce the length of the segment connected directly to the chimney as much as possible. Before filling the heater with water, a specialist is invited to personally set up the equipment and make sure that it works correctly.

An important role in piping a gas boiler is played by a thermostat. It simultaneously saves resources and optimal level comfort in the room (thanks to competent settings). Reducing the load of the boiler itself and the circulation pump also turns out to be quite profitable. Even the most expensive device justifies the investment already for the first heating season. For your information: when it comes time to turn off the boiler at the end of this season, it is undesirable to drain the water.



What else to read