Design features of the C2000-BKI. Design features C2000-BKI S2000 BKI adjustment removal taking

The S2000-BKI control and indication unit is used in conjunction with the s2000/S2000M console as part of the Orion ISO and performs the functions of displaying 60 system sections using built-in indicators, as well as remote control of specified sections. In addition, when a new event occurs, the device informs about this by issuing a sound signal.

The ability to control system partitions is implemented using 60 buttons that can be used to arm and disarm selected partitions, turn on and off actuators and reset alarms. When a button is pressed, the device sends a request to the network controller, which analyzes the received information and decides whether to execute the command or refuse to execute it.

The device provides the ability to implement limited user access to partition management. In this case, control is allowed after presentation of a pre-programmed identifier. During programming, each key is assigned the partitions that it can control and the allowed actions in the system.

For correct operation in the system, the S2000-BKI block is assigned its own address, to which data is sent and commands are received from the network controller. For each device in the system, this address must be unique.

The S2000-BKI block performs constant data exchange with the S2000/S2000M console. In cases where there is no communication via RS-485 for more than 60 seconds, the device transmits data indicating the time of the event (according to the internal clock). Verification and synchronization of time with the S2000/S2000M console is performed automatically at an interval of 1 hour.

Since all data is transmitted via the RS-485 interface, the unit can be located at a remote distance from the network controller. Such a need often arises in large distributed systems, when it is necessary to realize the possibility of control from several places, for example, from a fire station and a security room (or control room).

The S2000-BKI control and indication unit is a simple and functional device designed to provide visibility during operation and the ability to remotely control system sections.

transcript

1 INDICATION UNIT WITH KEYBOARD "S2000-BKI" (ver. 2.20) Label ATSDR ET ISO 9001 BB02 UP001 1 BASIC TECHNICAL DATA 1.1 General Information The indication unit with keyboard "S2000-BKI" (hereinafter the unit) is designed to work in the Orion system together with the devices included in its composition. The unit is designed for joint operation with the Signal-20, Signal-20P, S2000-4 fire and security control devices and the S2000-KDL two-wire line controller and allows using the S2000M console (hereinafter the console ) or AWP "Orion" to receive messages from these devices and the controller, display the status of the sections controlled by them on the built-in indicators and the sound signaling device, and control the sections (arm and disarm). signaling device of sections states received via RS-485 interface from a remote control or a computer The block is designed for arming and disarming sections its use in conditions of exposure to aggressive environments, dust, as well as in fire hazardous rooms. to mechanical influences, the block version corresponds to placement category 03 according to OST. In terms of resistance to environmental climatic influences, the block corresponds to version 03 according to OST, but for operation at temperatures from 243 to 323 K (from minus 30 to +50 C). 1.2 Main technical characteristics Power supply external direct current source with voltage from 10.2 to 28.4 V ("RIP-12", "RIP-24") Power consumption, 3 W. no more Current consumption, no more than Current consumption in standby mode (all indicators are off), no more than at supply voltage 12 V 200 mA; at a supply voltage of 24 V 100 mA. at a supply voltage of 12 V 50 mA; at a supply voltage of 24 V 50 mA Number of indicators Number of partitions Overall dimensions 170x340x25.5 mm Weight of the block, no more than 0.6 kg The block does not issue false notifications when exposed to external electromagnetic interference of the second degree of severity according to GOST R specified in GOST R The design of the unit ensures the degree of protection of the shell IP20 according to GOST. "S2000-BKI" ATSDR ET Amend.2 ATSDR from

2 The design of the block ensures its fire safety in emergency operation and in case of violation of the rules of operation in accordance with GOST Delivery set 1) Indication block with keyboard "S2000-BKI" ATSDR pcs. 2) Label ATSDR ET 1 copy. 3) Screw 1-3x GOST pcs. 4) Dowel 6x30 4 pcs. 5) Packing 1 piece 1.4 Functioning of the unit Operation modes of the unit are indicated by the "Operation" indicator according to the table: Operation mode Indicator status 1. Normal On 2. No communication via RS-485 interface Blinking at a frequency of 1 Hz 3. Programming mode (version update) Blinking at a frequency of 4 Hz If there is no exchange over the interface for s, the "Operation" indicator starts flashing at a frequency of 1 Hz (provided that the supply voltage is normal). When the exchange is resumed, the indicator switches to a continuous glowing mode Control buttons: Actions Disarming Arming Operator actions button when the partition status is "Released" There are two ways to control the arming/disarming of partitions using the buttons. 1) Without restriction of access to control by time. To do this, when configuring the unit using the "uprog.exe" program (see p), program the access key (digital password), which is also programmed with the appropriate control rights, allowed by the sections in the central controller under which the unit operates. 2) With limited access to control, using Touch Memory keys. In this case, control is possible within 30 s after touching the block reader with the key (the state of the external indicator is on). The keys must be programmed in the central controller with rights to manage the respective partitions The states of the partitions are displayed using the light indicators "1" "60": Section status "Armed" "Armed" "Request to arm" "Disarmed" "Alarm" "Attack" Status indicator light Red (green if the indication type is set to fire) Flashing green at 4 Hz Flashing green at 4 Hz Green (blinking green if the indication type is set to fire; off if the indication type is security 2 ) 2 "S2000-BKI" ATSDR ET Amend.2 ATSDR from

3 "Rejection" "Fire" "Attention" "Fault" "No connection" "Process loop failure" "Process loop normal" Continuation of the table Blinking green at a frequency of 1 Hz Blinking red at a frequency of 2 Hz Blinking red: 0.25 s on, 0.75 s off Flashing amber: 0.25 s on, 1.75 s off Flashing amber at 1 Hz If the indicator type is "Technological", flashing amber: 0.25 s on, 1.75 with no. If the indicator type is "Technological 2", it glows yellow. If the indicator type is "Technological", it is off. If the indicator type is "Technological 2", it is lit green Note If several messages are received in a row in any section, a message with a higher priority is displayed. By priority, messages are distributed as follows: "Fire", "Attention", "No connection", "Fault" for fire sections; "Attack", "Alarm", "No connection", "Rejection" for security and alarm sections. The section switches to the "FAULT" state in case of a malfunction (short circuit and break) of the loops, disconnection and malfunction of the addressable sensors, communication failure with the devices that control the section. "Access request" by Touch Memory "Access denied" by Touch Memory "Access confirmation" "No connection" Status of the buzzer On at a frequency of 2 Hz On at a frequency of 2 Hz 1.5 s on, 0.5 s off On 2 times per 0.25 s, 1.25 s off 0.25 s on, 3.75 s off On for 0.25 s On for 1 s On for 0.25 s On at a frequency of 2 Hz Reset the sound signal by pressing the "RESET" button ". In this case, the unit transmits the message "Operator reaction" to the console or workstation. The buzzer can be reset automatically after a certain time, which is selected when configuring the unit. In this case, the message is not sent to the console when the sound is reset. The status of the system indicators when alarm messages are received: The status of the "Alarm" section "Attack" "Missed" "Fire" "Attention" "Fault" "No connection" Indicator status Blinks red with a frequency 2 Hz Flashing red: 0.25 s on, 0.75 s off Flashing amber: 0.25 s on, 1.75 s off Flashing yellow at a frequency of 1 Hz "S2000-BKI" ADDR ET Change 2 ADDR from

4 1.4.6 To configure the block for a specific use case, it provides programming of the following parameters stored in non-volatile memory: Parameter name 1. Assigning a section number to indicators 2. Indication type Function description Range of allowable values ​​Default value (when the device is delivered) "Security" "Fire" "Technological" "Intrusion 2" "Technological 2" "Intrusion" 3. Response pause ms 3 ms 4. Network address 5. Type of control Device address when accessing it via the RS interface Arming/disarming Arming Not used Arming/disarming Note When the "Technological" indication type is set, the indicator displays only the "Technological loop violation" state External indicator state: "Access request" state "Access allowed" "Access denied" Indicator state Flashes at a frequency of 2 Hz On for 30 s Off To change configuration parameters unit uses a personal computer and "RS-232/RS-485 interface converter" (" PI") or remote control "S2000" version 1.20 and higher. The block configuration parameters are set using the "uprog.exe" program (version no lower). In the "uprog.exe" program, "S2000-BKI" is defined as "S2000-BI". The latest version of the device configuration program "uprog.exe", as well as additional information on using the unit, is available on the Internet at: The unit sends the following messages via the RS-485 interface: "Burglary alarm" ("Unit case open"); "Restoration of burglary control" ("The block body is closed"); "Operator reaction" (pressing the "Reset" button in the presence of alarm events); "Power failure" (supply voltage below the permissible level). If more than 60 s have passed from the moment of any event to the moment of its transmission (communication failure via the RS-485 interface), then the event is transmitted indicating the actual time according to the unit's internal clock. Synchronization of the internal clock in the block is carried out by the command "Time synchronization" (usually at each hour change) The block provides buffering of events transmitted via the RS interface "S2000-BKI" ADDR ET Change2

5 2 INSTRUCTIONS FOR OPERATION 2.1 Safety measures The design of the unit meets the requirements of electrical and fire safety in accordance with GOST and GOST The unit has no circuits under dangerous voltage Mounting, installation, maintenance should be carried out with the power supply of the unit switched off Installation and maintenance of the unit must be carried out by persons having a qualification group for safety measures not lower than the second. 2.2 Preparing the unit for use Using the "uprog.exe" program (see also p) program the following parameters. Change block address. This address must not match the address of any device connected to the same RS-485 interface as the unit. Select the algorithms for working with the buttons of the unit in accordance with p In accordance with the purpose of the unit, change, if necessary, the remaining configuration parameters of the unit Install the unit in a convenient place (installed on walls, on other structures of the room near the operator’s workplace in places protected from atmospheric precipitation, mechanical damage and access by unauthorized persons) Mount the unit and connecting lines in accordance with the connection diagram shown in the figure. The unit is mounted in accordance with the RD "Rules for the production and acceptance of work. Security, fire and fire alarm installations" If the unit and the network controller are connected to different power sources, then combine their "0 V" circuits If the unit is not the last one, remove jumper ("jumper"), located in close proximity to the contacts "RS-485A" and "RS-485B". RS-485B 1 RS-485A +U B 4 + U 5 Ind. 0 V TM To PKU "S2000M" or computer RS ​​V V (optional) 0 V To power supply +12 V V to Touch Memory reader 3 MAINTENANCE 3.1 General information . Annual maintenance work is carried out by an employee of the service organization and includes: checking the external condition of the unit; checking the unit's performance in accordance with clause 3.2 of this document; checking the reliability of fastening the unit, the condition of external mounting wires, contact connections. "S2000-BKI" ATSDR ET Amend.2 ATSDR from

6 3.2 Checking the operation of the block Preparation for checking the block: a) check the condition of the package and unpack the block; b) check the delivery set for compliance with clause 1.3 of this document, the presence and composition of spare parts and accessories; c) make sure that there is no mechanical damage to the block body; d) by shaking the block, make sure that there are no foreign objects inside it; e) check fastening of terminal blocks; f) check the block number and date of manufacture for compliance with those indicated on the label. Checking the general functioning of the block: a) apply power to the block; b) the light indicator "Operation" after s should start flashing at a frequency of 1 Hz (with the circuits of the RS-485 interface disconnected from the control panel); c) check the current consumption of the block, it should not exceed 200 mA. Checking the operation in the "Diagnostics" mode. In the "Diagnostics" mode, the functioning of the built-in indicators is checked. The "Diagnostics" mode is switched on using the "Reset" button. To enable the mode, it is necessary to carry out three short presses on the "Reset" button and one long press. A long press here means holding the button in the "pressed" state for at least 1.5 s. A short press means holding the button in the "pressed" state for 0.1 to 0.5 s. The pause between pressings should be at least 0.2 s and not more than 1 s. If the block is in good condition, the indicators "1" "60" turn on in the following order: 1) the columns turn on in turn in green, then red; 2) alternately turn on the lines in green, then red; 3) system indicators turn on one by one; 4) all "1" "60" indicators turn on yellow, then green; 5) all system indicators flash simultaneously; 6) when you press the buttons "1" "60" the corresponding indicator turns on. When you repeatedly press the same button, the corresponding indicator turns on alternately red, green and turns off. The "Diagnostic" mode is turned off automatically 30 seconds after the last pressing of one of the buttons "1" "60" or after pressing the "Reset" button Checking communication via the RS-485 interface. Connect RS-485 interface circuits to the console. Turn on the power supply of the unit and devices. The "Run" LED should turn on continuously. Within 1 minute after turning on the power, the remote control display should show messages about the detection of the block, about resetting the device with the address corresponding to the block. If you receive several messages that have accumulated in the buffer of the block, you can "scroll through" them using the " " and " " buttons on the remote control. Make an entry in the log of repairs and incoming control of the fire alarm system about the results of the check. Notes 1 Connection and disconnection of wires during checks should be carried out with the unit powered off. 2 Checks should be carried out taking into account the time of technical readiness of the unit (no more than 2 s). 6 "S2000-BKI" ADDR ET Amend.2 ADDR from

7 4 OVERALL AND INSTALLATION DIMENSIONS Rear view, 5 8 2 holes. for cable entry 3.4 2 slots, holes. 4.5 for wall mounting, MANUFACTURER'S (SUPPLIER'S) WARRANTY 5.1 The manufacturer guarantees that the unit complies with the requirements of the operational documentation, provided that the user observes the rules of transportation, storage, installation and operation. 5.2 The average service life of the unit is at least 10 years. 5.3 Warranty period of operation 18 months from the date of putting the unit into operation, but not more than 24 months from the date of release by the manufacturer. 5.4 When a unit is sent for repair, an act describing a possible malfunction must be attached to it. Complaints should be sent to the address: , Moscow region, Korolev, st. Pionerskaya, 4, CJSC NVP "Bolid". Tel./fax: (495) (multichannel), "S2000-BKI" ADDR ET Amend.2 ADDR from

8 6 INFORMATION ON CERTIFICATION Display unit with keyboard "S2000-BKI" ATSDR complies with the requirements of state standards and has: certificate of conformity to functional purpose ROSS RU.BB02.H04363; fire safety certificate SSPB.RU.UP001.V07357; production "S2000-BKI" has a certificate of GOST R ISO ROSS RU.IK.32.K DIFFERENCES FROM PREVIOUS VERSIONS Version Beginning of release Replacement version Contents of changes First serial version Compatibility "Uprog.exe" version not lower Console "S2000M" version not lower AWP "Orion" release 7.6 and higher, AWP "Orion PRO" release 1.11 and higher documentation, packed by CJSC NVP "Bolid" and found fit for use. Responsible for acceptance and packaging of QCD M.P. FULL NAME. day, month, year


INDICATION UNIT WITH KEYBOARD "S2000-BKI" (ver. 2.21) Label ATSDR.426469.030 ET ISO 9001 UP001 BB02 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Display unit with keyboard "S2000-BKI"

INDICATION UNIT WITH KEYBOARD "S2000-BKI" (ver. 2.22) Label ATSDR.426469.030 ET ME61 1 BASIC TECHNICAL DATA 1.1 General information

INDICATION UNIT OF THE FIRE EXTINGUISHING SYSTEM “S2000-BI isp. 01" (ver. 1.01) Label ATSDR.426469.015-03 ET 1 BASIC TECHNICAL DATA 1.1 General information

INDICATION UNIT "S2000-BI" SMD ver. 1.12 Label ATSDR.426469.015-01 ET 1 MAIN TECHNICAL DATA 1.1 General information

INDICATION UNIT OF THE FIRE EXTINGUISHING SYSTEM "S2000-PT" ver. 1.01 Label ATSDR.426469.015-02 ET ISO 9001 UP001 BB02 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Fire extinguishing system display unit

INDICATION UNIT "S2000-BI" version 02 ver. 2.23 Label ATSDR.426469.0-04 ET 1 MAIN TECHNICAL DATA 1.1 General information

FIRE EXTINGUISHING SYSTEM INDICATION UNIT "S2000-PT" (ver. 1.01) Label ATSDR.426469.015-02 FL 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Fire extinguishing system indication unit "S2000-PT" (hereinafter

ISO "Orion" Voice Announcement Unit 01 Installation manual АЦДР.425541.001-01 IM

ISO "Orion" Two-wire communication line controller Installation manual АЦДР.426469.012 IM

39 82 92 107 35 ISO "Orion" Two-wire communication line controller "S2000-KDL" Installation instructions ATSDR.426469.012 IM

SIGNAL-START UNIT "S2000-SP1" (ver. 1.56) Label ATSDR.425412.001 ET ME61 1 BASIC TECHNICAL DATA 1.1 General information

ISO 9001 SIGNAL-START UNIT "S2000-SP1 rev.01" (ver. 1.55) Label АЦДР.425412.001-01 ET BB02 UP001 1 BASIC TECHNICAL DATA 1.1 General information

CONVERTER OF INTERFACES USB/RS-485 "S2000-USB" Label ADDR.426469.029-01 ET ISO 9001 ME61 1 BASIC TECHNICAL DATA 1.1 General information

Transfer cabinet "ShVR-110" Label ATSDR.425532.002 ET 1 MAIN TECHNICAL DATA 1.1 General information

RESERVED POWER SUPPLY OF THE RIP-24 fire alarm system rev.01 Label ATSDR.436534.002-01 ME61

INDICATION UNIT OF THE FIRE EXTINGUISHING SYSTEM "S2000-PT" Label ATSDR.426469.015-02 ET This label describes the principle of operation and operating conditions of the indication unit "S2000-PT" v.2.01

CONVERTER OF INTERFACES USB/RS-485 "S2000-USB" Label ADDR.426469.029 ET ISO 9001 ME 61 1 BASIC TECHNICAL DATA 1.1 General information

POWER SUPPLY MIP-12 version 02 (MIP-12-1/P3) Label ATSDR.436434.002 ET 1 MAIN TECHNICAL DATA 1.1 General information 1.1.1 Power supply MIP-12 version 02 (MIP-12-1/P3) ( hereinafter MIP) is intended

ADDRESSED SIGNAL-START BLOCK "S000-SP", version 0 (version.0) Label ATSDR.5.00-0 THIS IS THE MAIN TECHNICAL DATA. General information.. This label describes the block signal-starter addressable

ADDRESSED SIGNAL-START UNIT "S2000-SP4/24" Label ATSDR.425412.016 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 This label describes the S2000-SP4/24 addressable signal-start unit

CONVERTER OF INTERFACES USB/RS-485 "S2000-USB" ADCDR operation manual. 426469.029-01 REP 2018 CONTENTS 1 GENERAL INFORMATION... 4 2 TECHNICAL CHARACTERISTICS... 4 3 COMPLETENESS... 4 4 DESIGN,

CONVERTER OF INTERFACES USB/RS-232 "USB-RS232" Operation manual АЦДР.426469.033 REP 2018 CONTENTS 1. GENERAL INFORMATION... 4 2. TECHNICAL CHARACTERISTICS... 4

SWITCHING DEVICE UK-VK UK-VK version 10 UK-VK version 11 UK-VK version 1 UK-VK version 13 UK-VK version 14 UK-VK type 15 1.1 General information 1.1.1 This label

INDICATION UNIT OF THE FIRE EXTINGUISHING SYSTEM "S2000-PT" Label ATSDR.426469.015-02 ET This label describes the principle of operation and operating conditions of the indication unit "S2000-PT" v.2.50

INDICATION UNIT WITH KEYBOARD "S2000-BKI" Label АЦДР.426469.030 ET 1 BASIC TECHNICAL DATA 1.1 General information

ISO 9001 RESERVED POWER SUPPLY FOR EQUIPMENT OPS “RIP-12 isp. 06» Label АЦДР.436534.001-12 ET ПБ01 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply for equipment

SIGNAL-START UNIT "S2000-SP1" Label ATSDR.425412.001 ET 016 1 BASIC TECHNICAL DATA 1.1 General information

Operating instructions Redundant power supply without battery RIP-12 version 03 for battery 7 Ah 242872

CONVERTER OF INTERFACES USB/RS-485 "S2000-USB" Label ATSDR.426469.029-01 ET ME61 1 BASIC TECHNICAL DATA 1.1 General data

A complex of technical means for providing feedback to the premises of the fire station-control room SOUE ISO 9001 "Rupor-Dispatcher" АЦДР.424255.002 PS Passport 1 BASIC DATA 1.1 Complex of technical

INDICATION UNIT "S2000-BI SMD" Label ATSDR.426469.015 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 The indication unit "S2000-BI SMD" (hereinafter referred to as the unit) is designed to work as part of ISO "Orion"

USB/RS-485 INTERFACE CONVERTER “USB-RS485” ADC Operation Manual. 426469.032 REP 2018 CONTENTS 1 GENERAL INFORMATION... 4 2 TECHNICAL CHARACTERISTICS... 4 3 COMPLETENESS... 4 4 DESIGN,

The complex of technical means for providing feedback ISO 9001 with the premises of the fire station-dispatching SOUE "Rupor-Dispatcher". АЦДР.424255.002 PS Passport 1 BASIC INFORMATION 1.1 Complex of technical

SIGNAL-START UNIT "S2000-SP1 rev.01" Label АЦДР.425412.001-01 ET 1 BASIC TECHNICAL DATA 016 1.1 General information

INDICATION UNIT OF THE FIRE EXTINGUISHING SYSTEM "S2000-PT" Label ATSDR.426469.015-02 ET This label describes the principle of operation and operating conditions of the indication unit "S2000-PT" v.2.60

INDICATION AND CONTROL UNIT "Potok-BKI" Label АЦДР.426469.034 ET This label describes the principle of operation and operating conditions of the indication unit "Potok-BKI" v.1.00. 1 MAIN TECHNICAL DATA

INDICATION UNIT "S2000-BI isp.02" Label ATSDR.426469.015-04 ET 1 BASIC TECHNICAL DATA 1.1 General information

ISO "Orion" Fire and security control panel "Signal-20P isp.01", "Signal-20P SMD" Installation instructions ATSDR.425533.001-01 IM

ISO "Orion" Fire and security control panel "Signal-20P isp.01", "Signal-20P"

ISO 9001 CONVERTER OF INTERFACES USB/RS-232 "USB-RS232" Label ADDR.426469.033 ET ME61 1 BASIC TECHNICAL DATA 1.1 General information

ISO 9001 RESERVED POWER SUPPLY FOR EQUIPMENT OPS "RIP-12" isp. 02P Label ATSDR.436534.001-13 ET PB01 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply for equipment

ADDRESSED SIGNAL-START BLOCK "S2000-SP4/220" version 1.04 ATSDR label. 425412.015 FL 1 MAIN TECHNICAL DATA 1.1 General information 1.1.1 This label describes the signal-starting unit

ISO "Orion" Fire and security control panel These installation instructions contain instructions that allow you to perform the basic steps for installing and preparing the "Signal-20M" device for operation.

SIGMA BIS-R group of companies Status indication unit Operation manual SAKI.425548.002 RE ASB Rubicon Operation manual. SAKI.425548.002 RE. Status indication block "BIS-R" Revision

INDICATION UNIT WITH KEYBOARD "S2000-BKI" Label АЦДР.426469.030 ET 1 BASIC TECHNICAL DATA 1.1 General information

START CONTROL UNIT "S2000-KPB" (ver. 1.09) Label АЦДР.425412.003 ET UP001 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1

CONVERTER OF INTERFACES USB/RS-485 "USB-RS485" Label ADDR.426469.032 ET ISO 9001 ME61 1 BASIC TECHNICAL DATA 1.1 General data Converter of interfaces USB/RS-485 "USB-RS485" ADDR.426469.032

RESERVED POWER SUPPLY FOR RIP-12 OPS EQUIPMENT 05 Label ATSDR.436534.001-09 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply for RIP-12 fire alarm equipment

INDICATION UNIT "S2000-BI isp.02" Label ATSDR.426469.015-04 ET 1 BASIC TECHNICAL DATA 1.1 General information

CONTACTLESS DESK READER «Proxy-USB-MA» Operation manual АЦДР.425729.007 REP 2018 CONTENTS

SIGNAL-START UNIT "S2000-SP1 version 01" Label АЦDR.425412.001-01 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Signal-starter unit "S2000-SP1 version 01" (ver. )

CONVERTER OF INTERFACES USB/RS-485 "USB-RS485" Label ADDR.426469.032 ET ME61 1 BASIC TECHNICAL DATA 1.1 General information

CONTACTLESS READER "S2000-Proxy N" Operation manual АЦДР.425729.004 REP 2018 CONTENTS 1 GENERAL INFORMATION... 4 2 TECHNICAL CHARACTERISTICS... 4

BLOCK SIGNAL-START ADDRESSED "S2000-SP2 isp. 02» Label ATSDR.425412.004-02 ET 1 MAIN TECHNICAL DATA 1.1 General information 1.1.1

RESERVED POWER SUPPLY RIP-12 version 05 (RIP-12-8/17M1) Label ATSDR.436534.001-09 FL 1 MAIN TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply RIP-12 version 05 (RIP-12-8 /17M1)

VOICE ALARM DEVICE "SHOUT" isp. 01 (ver. 1.01) Label ATSDR.425541.001-01 ET 1 MAIN TECHNICAL DATA 1.1 General information 01 (hereinafter referred to as the device) is intended

ISO "Orion" Voice Annunciation Unit "Rupor" Installation manual АЦДР.425541.001 IM

RESERVED POWER SUPPLY FOR OPS EQUIPMENT RIP-24 version 01 (RIP-24-3/7M4) Label АЦДР.436534.002-01 1 MAIN TECHNICAL DATA 1.1 General information 1.1.1 Redundant power supply for equipment

MODULE FOR CONTROL OF THE STATE OF RESERVED POWER SOURCES "MKS RIP" Label АЦДР.468213.001 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Module for monitoring the status of redundant sources

ISO "Orion" Security and fire control panel S000M Installation manual АЦДР.46469.07 IM

CONTACTLESS READER «Proxy-Н1000» (WITH ACCESS CONTROL FUNCTION) Operation manual АЦДР.425728.001 РЭп 2018

INDICATION AND CONTROL UNIT "Potok-BKI" Label АЦДР.426469.034 ET This label describes the principle of operation and operating conditions of the indication unit "Potok-BKI" v.2.00. 1 MAIN TECHNICAL DATA

POWER SUPPLY MIP-12 version 01 (MIP-12-1/7P3) Label ATSDR.436434.001 ET 1 BASIC TECHNICAL DATA 1.1 General information 1.1.1 Power supply MIP-12 version 01 (MIP-12-1/7P3) ( hereinafter MIP) is intended

SIGNAL-START UNIT "S2000-SP4/24" Label АЦДР. 1.1 General information

Description of C2000-BKI

Display block C2000-BKI designed to work as part of the Orion burglar alarm, manufactured by NPO Bolid. The block provides manual control of 60 sections of the system and display of events in these sections using built-in indicators and sound signaling.

The control of the S2000-BKI unit is carried out using the S2000M remote control or a computer with the Orion PRO workstation installed.

Block S2000-BKI works with the following devices: Signal-10, Signal-20, Signal-20M, Signal-20P isp.01, Signal-20P SMD, S2000-4, S2000-KDL.

Partition status indication:

  • Light and sound signaling of events in 60 sections of the security system. Control of possible partition states: Armed, Armed, Removed, Alarm, Attack, Non-armed, Fire, Attention, Malfunction, Technological AL violation, Technological AL norm
  • Display of the alarm and malfunction of a part of the Orion system using separate indicators: Fire, Attention, Alarm, Attack, Absence, No connection and Fault.

Design features of C2000-BKI:

  • Built-in keyboard for manual control of 60 partitions
  • Partition management (arm/disarm):
    - limited access using Touch Memory key
    - no access restriction using only the keyboard
  • Checking the functionality in the Diagnostics mode
  • Built-in sounder
  • Reset button to turn off the beep
  • Tamper sensor
  • Non-volatile memory
  • Control via RS-485 interface
  • External Touch Memory Reader Connections
  • Time synchronization with the S2000, S2000M remote control
  • Possibility of connection of 2 independent power supplies.