Compact heat meter pulsar instruction. Apartment heat meter compact pulsar

The Pulsar heat meter is a small device with which the energy consumption is determined by measuring the temperature and the amount of heat carrier flow. In addition, it takes into account the amount of pulses coming from devices with a similar output. "Pulsar" is a heat meter equipped with a calculator and converters (flow and resistance). The device measures the volume and temperature of water moving through the pipes (main, return), after which the data is processed and displayed on a liquid crystal display.

Device Features

The price set for the Pulsar heat meter may seem high to some, but these costs pay off in the shortest possible time. In addition, by purchasing a device on the manufacturer's website or through official distributors, you can save a lot. The apartment heat meter "Pulsar" is able to determine the excess of the volume of "too" hot water. It can be used in dead-end plumbing systems. The device is equipped with an RS485 interface. There are also models with pulse or radio output. The choice depends on the parameters of the serviced equipment.

With how to take readings of the Pulsar compact heat meter, even non-professionals will not have problems. The main parameters are displayed in turn on the screen. You can watch:

  • volume of water, m³;
  • temperature in pipelines, °C;
  • the difference between the main line and the "return", ° С;
  • thermal energy, Gcal;
  • instant consumption and thermal power, m3/h and Gcal/h;
  • date, etc.

The price of the Pulsar heat meter is also quite high due to the presence of non-volatile memory. The archive stores data and calculations for 180 days. A special event log captures errors that may occur in a workflow.

Error alerts

The readings of the Pulsar heat meter should be stopped in cases where a signaling icon appears on the screen. For example, when the battery is discharged, the symbol depicting it begins to flicker. If the thermometers are flashing, then there is a negative temperature difference in the pipes. If there is a memory problem, a leaf with a bent upper right corner appears. All icons indicating the need to stop the Pulsar heat meter to correct malfunctions can be found in the instructions.

Mounting

This converter can be installed both in the main and in the return pipeline. This must be taken into account when choosing a design. Do not mount the device near sources of radiation and in places where there is a possibility of exposure to aggressive gases, vibration, moisture and dust. Installation of the heat meter "Pulsar" and its inclusion must be carried out in strict accordance with the instructions of the equipment supplier. Maintenance and verification are carried out according to the schedule.

If you are interested in buying a Pulsar heat meter in Moscow or would like to get more information about this device, we invite you to visit our website. Our experts will answer all your questions promptly and in detail.

2. Temperature 3. Pressure 4. Flow 5. Level 6. Automation and secondary devices 7. Analytics

Teplopribor group of companies (GC) (Teplopribor, Prompribor, Teplokontrol, etc.)- these are devices and automation for measuring, controlling and regulating the parameters of technological processes (flow metering, heat control, heat accounting, control of pressure, level, properties and concentration, etc.).

At the price of the manufacturer, products are shipped both of our own production and of our partners - leading factories - manufacturers of instrumentation and automation, control equipment, systems and equipment for managing technological processes - process control systems (much is available in stock or can be manufactured and shipped as soon as possible) .

Apartment heat meter PULSAR-K

Apartment heat meter - KTS / heat meter PULSAR-K tachometric (vane, single-jet) type is designed to measure thermal energy, volume and temperature of the coolant, as well as to count the number of pulses generated by metering devices with a pulse output. It is used in systems of central water heating of individual consumers (apartments / apartment accounting, townhouses, individual houses / cottages, small offices, trade pavilions / shops and other premises up to 200-250 m2).

Heat meter PULSAR-K designed for operation in closed heating or cooling systems (as a cold meter). The heat meter can be used to measure heat in a dead-end hot water system, like a hot water meter that determines the volume of water whose temperature is above a set value.

Heat meters PULSAR-K are supplied both without interfaces and with interfaces: RS485, M-Bus, pulse output, radio channel. The choice of interface is carried out when ordering the device.

The cost of an apartment heat meter PULSAR-K depends on the version (modifications, see table below), prices for additional options, total order volume and other pricing factors ().

The price of the heat meter PULSAR-K (basic modification of the heat meter) - approximately from 6370 rubles *

Symbol for modification of the heat meter (heat meter) Description Du-15
Price* rub, without cash
Du-20
Price* rub, without cash
Pulsar-1 with radio output (radio channel) 6 370 7 340
Pulsar-2 with digital output (RS485, M-Bus) 7 090 7 940
Pulsar-3 with pulse output 6 990 7 840
Pulsar-4 with visual reading 7 980 8 830

(the price is indicated without VAT, the cost of additional equipment and packaging, shipping and / or delivery costs, based on a small wholesale order (for a wholesale order, you can buy a batch with significant discounts on the price) and is subject to clarification when ordering, possible discounts and options on how to buy inexpensively: for project orders, the price is formed individually based on the volume and address of the object).

Functional features and advantages of PULSAR-K apartment heat meters:

— high-precision measurement of temperature difference from 0.25 °С — can be mounted in studio apartments;
— heat accounting in Gcal;
— can be used as hot water meters;
- LCD display in Russian;
— various data transfer interfaces;
— open exchange protocol, software for reading data;
— compact dimensions, removable heat calculator;
- touch button;
— function of self-diagnostics;
— measurement of thermal energy and cooling energy;
— there is a modification with 4 pulse inputs;
— calibration interval (MPI) — 6 years.

Measured parameters of the heat meter PULSAR-K (apartment heat meter):

— thermal energy, (Gcal/Mcal);
- the volume of the coolant, m 3;
— coolant temperature in the supply and return pipelines, ºС;
- temperature difference in the supply and return pipelines, ºС;
- instantaneous flow rate of the coolant, m 3 / h;
— instant thermal power, (Mcal/h);
— diagnostic messages, error codes;
- date and time;
- network address.

Technical characteristics of the apartment heat meter PULSAR-K

Compact apartment heat meterPULSAR-K consists of a flow transducer, a calculator and a set of platinum resistance thermocouples, heat meters PULSAR-K, depending on the modification (see the table above) can be equipped with 4 interface outputs: radio channel, digital output, pulse or visual reading.

The principle of operation of the heat meter PULSAR-K consists in measuring the volume and temperature of the heat carrier in the supply and return pipelines, followed by the determination of thermal energy by processing the measurement results with a calculator. Heat meters PULSAR-K can be used as hot water meters , defining the volume of water, the temperature of which is higher than the specified value.
The volatile memory of heat meters registers:
- monthly values ​​of thermal energy (not less than 18 months),
-daily values ​​(not less than 180 days)
- hourly values ​​(not less than 45 days).

Interfaces -RS485, M-BUS, Wireless M-BUS - for Pulsar-2 heat meters with digital output.

Software (software) for the apartment heat meter Pulsar-K is a HeatMeter2_V1 firmware installed at the factory and protected from modification by a 128-bit MD5 hash algorithm. The software also includes the TestAll program with calibration, adjustment and verification functions.

Main metrological parameters and technical characteristics of heat meters PULSAR-K

Nominal diameter, DN, mm 15 20
Minimum volume flow, qi, m3/h 0,012 0,02 0,03 0,05
Maximum volume flow*, qp, m3/h 0,6 1,0 1,5 2,5
Limit volume flow, qs, m3/h 1,2 2,0 3,0 5,0
Sensitivity threshold, m3/h 0,004 0,006 0,008 0,015
Weight of the device, g, no more 700 900
* Gmax - in accordance with the Order of the Ministry of Construction of Russia dated March 17, 2014 No. 99 / "On approval of the Methodology for the implementation of commercial accounting of heat
energy, coolant.
Parameter (characteristic) of the heat meter PULSAR-K Parameter value (characteristics)
Limits of permissible relative error in measuring the amount of energy (thermal power),%,: ±(3+4 Δtmin/Δt+0.02 qp/q)
Limits of permissible relative error in measuring the volumetric flow rate (volume) of the coolant, %,: ±(2+0.02 qp/q), but not more than 5
Flow measurement dynamic range q i /q p 1:50
Temperature measurement range, ºС from 1 to 105
Maximum temperature 105 °C or 130 °C on special order
Limits of permissible absolute error of temperature measurements, °C ±(0.6+0.004 t)
Temperature difference measurement range, Δt, ºС from 3 to 104
Limits of permissible relative error of a set of temperature sensors, % ±(0.5+3 Δtmin/Δt)
Limits of permissible relative error of the calculator, % ±(0.5+Δtmin/Δt)
Limits of permissible relative error of current time measurements, % ±0.05
Metrological class 1 or 2
Maximum working pressure, MPa 1,6
Operating conditions:
ambient air temperature range, °С, at: a) operation
b) storage
relative air humidity range, %
atmospheric pressure range, kPa
from +5 to +50
-40 to +55
from 20 to 95
from 61 to 106.7
Dust and water protection class according to GOST 14254 IP54
Average service life, years, not less 12
Length of connecting cables of thermal converters, mm (other values ​​are possible on request) 1500
Length of connecting cables of interfaces, mm (other values ​​are possible on request) 1000
DC battery voltage, V 3.60.1
Battery life, years, not less 6
Radio module characteristics:
operating frequency band, MHz
output power, mW, no more
433.075 to 434.479 (868.7 to 869.2)
10 (25)
Interface connection parameters: RS485 M bus
Speed 9600 2400
Stop bits
Parity
1
None
1
even
bits 8 8
Network address Corresponds to serial number 0
Number of additional counting inputs (on request) 4
Number of pulse outputs (optional) 1
Interface supply voltage, V 9…30
Current consumption from an external source RS485/M-Bus, mA, no more 10
Instrument indicator LCD, 8 digits + special characters
Data archive in non-volatile memory 60 Months, 184 days, 1488 hours
Maximum energy value, Gcal 9999,9999
Maximum value of coolant volume, m3 99999,999
Overflow thresholds for pulse inputs 100000000,0
Pulse output pulse duration, ms (other values ​​are possible on request) 125
Pulse weight, Gcal (other values ​​are possible on request) 0,001
Maximum switching current of the pulse output, mA 50
Maximum switching voltage of the pulse output, V 24

Overall and mounting dimensions of the heat meter PULSAR-K (apartment heat meter)

Parameter (characteristic) of the heat meter PULSAR-K (apartment heat meter) Parameter value (characteristics)
Nominal diameter, mm 15 20
Carving of fittings for connection to the pipeline, inches 1/2″ 3/4″
Thread on the body of heat meters, inches 3/4″ one"
Overall dimensions (LxWxH), mm 125x105x160 135x105x160
Mounting length, mm 110 130
Weight, kg 0,85 0,95

Delivery package of the apartment heat meter PULSAR-K

.The package of delivery of the apartment heat meter PULSAR-K includes:

Form of designation entry when ordering an apartment heat meter PULSAR-K

When placing an order for an apartment heat meter PULSAR-K you should specify the modification (-1, -2, -3, -4 according to the table of modifications at the beginning of the page), Du, and also, in case of choosing a heat meter PULSAR-2 with a digital output, you should specify the type of interface.

An example of placing an order (recording how to buy):
Pulsar-K heat meter complete with Du-15 connectors and a ball valve with holes. under the temperature sensor Du-15.

Additional equipment for heat meters for apartments (P:ULSAR-K and other apartment heat meters):
- a set of fittings (connectors) - the price is from 98 rubles * for DN15, in stock;
- ball valve with a tap (hole) for a temperature sensor - the price is from 169 rubles * for DN15, in stock;
— equipment and systems for dispatching (selection on request).

Analogues and possible replacements individual residential heat meters PULSAR-K (abbreviated):
1. Tachometric flowmeter type(turbine, vane): STK-Mars-Du15/Du20, Teplouchet-1-Du15/Du20, T-21-KOMBIK-T-Du10/Du15/Du20, ELF-15/20mm, PULSAR-K-Du15/Du20, KARAT-Compact-Du15/Du20, PULSE ST-15A/15B, KST-22-Du15-Kombik, STE-21-BERYL-15/20mm.

2. Ultrasonic type flow meter: STK-U-MARS-Du(15-40), SMALT-15-termo, PULSE-STU-Du15/Du20, BEREGUN-15/20/25mm, AVEKTRA-TSU-15/20/25mm, ULTRAHEAT-T230, ULTRAHEAT-T350/2WR6-Dn-15mm/20mm, MULTICAL-302-Dn-15mm/20mm, MULTICAL-402-Dn(15…50mm).

Possible errors when placing an order for a heat meter for PULSAR-K apartments

When ordering paddle dry-propelled heat meter for apartments PULSAR-K (apartment heat meter) We recommend that you be careful when placing an order, incl. take into account the possible variants of the designation and the errors encountered when ordering. For example, we have encountered such errors in applications:
- incorrect or incorrect name of the device: heat meter, heat water meter, heat meter, heat meter, heat meter, heat calculator, heat calculator, heat energy meter, cold recorder, detector, converter, sensor and other errors in the designation of the device ..
- incorrect model designations and spelling errors: Pulsor, Pulsar-T, Puls-T, Puls-K, etc.
- spelling errors related to translation, transliteration or keyboard layout, for example: apartment heat meter Pulsar-k, kvartirnyj teploschetchik pulsar-k, Gekmcfh-R, Gekmcfh-1…-4 (in En-layout), etc. etc.

Therefore, we kindly ask you to be careful when placing an order for a Pulsor-K heat meter, do not confuse the designations, and if you do not know or are not sure, then simply write the main technical characteristics and operating conditions in a simple form, and the engineers of our company will select the device you need and additional equipment at the best ratio Price - Quality - Production time (availability in stock).

Technical documentation for the heat meter PULSAR-K:
see the PULSAR-K heat meter order card (download the questionnaire).
see Technical specifications PULSAR-K apartment heat meter (Technical description).
see Operation manual PULSAR-K apartment heat meter (individual KTS meter).
see Method of verification PULSAR-K apartment heat meter.
At the request of the consumer, an order card (form) (questionnaire), a technical data sheet of the product, a certificate of conformity, a certificate of approval of the type of MI measuring instruments, permissions for use, a technical description and an operating manual, a description of the type of MI and a verification procedure, and as well as other permits and technical documentation.

We will be glad if the above information was useful to you, and we also thank you in advance for contacting any of the representative offices of the Teplopribor group of companies (three Teplopribor, Teplokontrol, Prompribor and other enterprises) and promise to make every effort to justify your trust.

PULSAR Mechanical apartment heat meters

Pulsar counter for heating in an apartment - maximum energy savings

Almost every apartment owner has faced unfair, in his opinion, the cost of heat supply services. Often, the calculation of the amount that must be paid for the received heat is carried out at inflated and unreasonable tariffs. In such cases, an individual meter for heating in an apartment will help solve the problem.

Apartment heat meters Pulsar- special devices that are designed to account for the consumption of thermal energy of the heating system of a separate dwelling. Their installation will allow you to effectively regulate energy consumption and really save on utility bills.

Measuring an individual heat meter Pulsar produces on the fact of the flow of the coolant and the difference in temperature at the inlet and outlet of the pipes of the heating system through which the coolant flows. Each device is equipped with a thermal energy consumption sensor and a pair of temperature sensors. They are connected to a calculator, which calculates the consumed heat energy.

Mounted heat meters Pulsar to an apartment in rooms where an autonomous input of the coolant is provided, as well as a horizontal wiring of the heating pipe system. If a vertical wiring is installed in the apartment, accounting is possible only with the participation of common house devices and a heat distributor.

The order in which they are used apartment heat meters Pulsar, provides for obtaining a special permit, project development and coordination of installation in various municipal authorities. And only after receiving all the documents, the installation itself follows.

Self-installation of the device is prohibited. The owner of the apartment needs to involve representatives of the organization providing heat supply in this area or use the services of installers from one of the construction companies that hold the necessary license.

Heat meter Pulsar set according to the following requirements:

— Installation of equipment is carried out in accordance with its passport and project documentation provided by the supplier of thermal energy.

- The device must be installed outside the living quarters, unless there is a special permission from the regulatory authorities for this.

- The installation of apartment heat meters should be carried out in such a way that the likelihood of the formation of "air pockets" is completely absent.

- Mandatory exposure of straight sections of the water supply near the installation site of the device is required.

A high-quality heat consumption meter is capable of measuring heat energy, heat carrier volume, its temperature in the supply and return pipelines, instantaneous heat carrier flow and heat output, as well as sending some diagnostic messages.

Technical details Models
Flow sensor type Mechanical single jet
Nominal diameter, mm 15 20
Minimum flow rate, qi, m3/h 0,006* 0,012 0,03 0,05
Nominal flow, qp, m3/h 0,6 0,6 1,5 2,5
Maximum flow rate, qs, m3/h 1,2 1,2 3 5
Starting flow, m3/hour <0,002 <0,004 <0,008 <0,015
Pressure loss at qp, MPa <0,025
1 or 2
1:50
Nominal pressure, MPa 1,6
Maximum temperature, °C 105,(130 optional)
3 — 104
0,25
Indicator LCD, 8 digits + special characters
Heat units Gcal
Connecting thread G3/4B G3/4B G3/4B G1B
Length, mm 110 110 110 130

* Execution by special order

PULSAR Ultrasonic apartment heat meters

Ultrasonic meter for heat energy metering

Pulsar ultrasonic heat meter designed to measure the exact amount of heat consumed.

The use of the device in commercial or technological accounting is approved by the type certificate of measuring instruments No. 64247. This allows us to expect that the general house accounting of thermal energy will be as accurate and fair as possible.

Using a common house heat meter Pulsar in the process of accounting for energy consumption, you can get accurate readings.

The principle of operation of the Pulsar common building heat meter is based on the calculation of consumed heat using information contained in the flow sensor and temperature sensors.

At the same time, the Pulsar home heat meter measures the volume of water entering the system and its temperature at the inlet and outlet.

Most often, a common house heating meter is installed on a horizontally located pipe. This method allows you to measure data from the entire apartment without the help of additional devices. The calculator of the device, based on the initial data, determines the amount of heat consumed and records the received data in the archive.

Features of the ultrasonic heat meter Pulsar

— Reliability. The design does not provide for any driving components prone to rapid wear.

- Versatility. Mounting in horizontal or vertical position is allowed.

- Ease of maintenance and operation.

- Wide functionality and measurement range.

- Accuracy. No pressure loss.

- Long service life - about 20 years. Warranty period 4 years.

— Ideal equipment. Devices are additionally equipped with a set of connectors

As a rule, an ultrasonic-type common house heating meter is used in apartment buildings. It takes measurements using an ultrasonic signal passed through hot water. The standard equipment includes a device that gives a signal, as well as reflectors "mirrors" that are mounted opposite each other.

An ultrasonic common house meter for heating, as a rule, uses two flow meters for both the supply and return pipelines.

The original scheme of a heat meter that works simultaneously with two flow meters in heat meter Pulsar allows you to significantly reduce the total cost of the heat metering unit.

If the power supply in the house is unstable, the device should be connected via UPS.

The main advantages that distinguish the ultrasonic heat meter of our production are information content and the absence of an increase in hydraulic pressure, and the original design.

Ultrasonic heat meter Pulsar: heating costs

According to the current legislation on the territory of the Russian Federation, general house heat metering is mandatory for installation. Currently, a fairly common scheme is used for the calculation. The tariff cost of heating per square meter is recognized, after which the meter readings are multiplied by the current cost. This figure is divided by the area to be heated.

Ways to save heat

For careful consumption of heat, experts recommend installing special metering devices in apartments. Based on the readings they record, residents can only pay for the energy resource they have consumed. In the case of the correct setting of the thermostats, it becomes possible to build the most suitable temperature in each individual room.

Technical details Models
Flow sensor type ultrasonic
DU 15 20
Minimum flow qi, m3/h 0,006 0,015 0,025
Nominal flow qp, m3/h 0,6 1,5 2,5
Maximum flow qs, m3/h 1,2 3,5 6
Starting flow, m3/h <0,002 <0,003 <0,005
Pressure loss at qp, MPa <0,025
Metrological class (EN1434) 1 or 2
Flow measurement dynamic range qi/ qp 1:100
Nominal pressure, MPa 1,6
Maximum temperature, °C 105, (130 on request)
Temperature difference measurement range, °C 3-104
Temperature difference to start energy counting, °C 0,25
Indicator LCD, 8 digits + special characters
Heat units Gcal
Readout interfaces
Data archive in non-volatile memory 60 months, 184 days, 1488 hours
Connecting thread G3/4B G3/4B G1B
Length, mm 110 110 130


PULSAR Ultrasonic heat meters

Household heat meter Pulsar ultrasonic with visual reading

Heat meters Pulsar allow you to control the flow of coolant in an apartment, office, shop and any other facility with the ability to automatically read data via radio or wire.

The device and principle of operation of the heat meter Pulsar

Heat meter Pulsar includes a calculator, a flow transducer, which can be both mechanical and ultrasonic, a set of resistance thermal transducers.

The principle of operation of the devices is based on measuring the temperature and volume of the coolant in pipelines and the subsequent calculation of thermal energy. It is possible to use an apartment heat meter in a dead-end DHW system, as well as a device for measuring the volume of hot water with a temperature above a given value.

The devices have the function of issuing diagnostic messages, fixing the date and time of events, reading the network address, determining the instantaneous flow rate of the coolant and the instantaneous thermal power.

You can get more detailed information about the proposed heat meters from our specialists.

For heating systems with vertical wiring, it is recommended to use the radiator heat energy distributor Pulsar

Measured parameters of the heat meter Pulsar

— thermal energy, (Gcal/Mcal);

— coolant volume, m3;

— coolant temperature in the supply and return pipelines, ºС;

- temperature difference in the supply and return pipelines, ºС;

— instantaneous coolant flow rate, m3/h;

— instant thermal power, (Mcal/h);

— diagnostic messages;

- date and time;

- network address.

Technical details Models
Flow sensor type ultrasonic
DU 25 32 40 50 65
Minimum flow qi, m3/h 0,035 0,06 0,1 0,350 0,250
Nominal flow qp, m3/h 3,5 6 10 35 25
Maximum flow qs, m3/h70 7 15 20 70 130
Starting flow, m3/h <0,007 <0,012 <0,02 <0,07 <0,05
Pressure loss at qp, MPa <0,025
Metrological class (EN1434) 1 or 2
Flow measurement dynamic range qi/ qp 1:100
Nominal pressure, MPa 1,6
Maximum temperature, °C 105, (130 on request)
Temperature difference measurement range, °C 3-104
Temperature difference to start energy counting, °C 0,25
Indicator LCD, 8 digits + special characters
Heat units Gcal
Readout interfaces pulse output (energy), M-BUS, Wireless M-BUS, RS485, optical, radio channel
Data archive in non-volatile memory 60 months, 184 days, 1488 hours
Connecting thread G1 1/4B G1 1/2B G2B
Length, mm 160 180 200 220 260

What else to read